11.0Test Procedures for Complete Twin-Path® Sling Products |
11.1 |
For proof testing, the pins shall be 1” diameter or larger.
|
11.2 |
Proof tests shall consist of pulling the slings to twice their rated capacity. Slings shall be held at the proof test
limit for a minimum of 15 seconds and then the tension may be released.
|
11.3 |
Testing of Twin-Path® Sling products and load yarn shall be on a testing machine, which meets or exceeds the standards
as described in ASME E-4.
|
11.4 |
Break testing of slings shall be as above with results documented. Pin size for break testing should be a diameter equal
to half the nominal sling width, or larger.
|
11.5 |
Proof testing is mandatory for every newly manufactured and repaired Twin-Path® sling.
|
11.6 |
After the sling is proof tested, the Tell-Tails should then be trimmed to length prior to shipment.
|
11.7 |
Repaired fittings or slings shall be proof-tested before they are returned to service.
THESE RECOMMENDED STANDARD SPECIFICATIONS HAVE BEEN FORMULATED AS A GUIDE TO USERS, INDUSTRY AND GOVERNMENT TO INSURE TH